MIL-STD-1247D
5. DETAILED REQUIREMENTS
5.1 Function.
5.1.1. Colors. Colors conforming to FED-STD-595 as shown in 2.2.1 shall be used to denote function as specified in 5.1.1.1.
5.1.1.1 Application of colors. Color coding shall be based upon function as indicated below. Where more than one color is required to identify a single function the order of colors is from left to right, and the colored area shall be composed of vertical stripes, of equal width, of the required colors (see figures 2 and 4).
Function Color
Fuel Red
Rocket Oxidizer Green, Gray Rocket Fuel Red, Gray Water Injection Red, Gray, Red Lubrication Yellow Hydraulic Blue, Yellow Solvent Blue, Brown Pneumatic Air Orange, Blue Instrument Air Orange, Gray Coolant Blue
Breathing Oxygen Green
Air Conditioning Brown, Gray Monopropellant Yellow, Orange Battery Activator Yellow, Gray Rain Repellants Blue, Gray
Vacuum Gray, Orange, Gray
Fire Protection Brown
De-Icing Gray
Rocket Catalyst Yellow, Green Compressed Gas Orange Electrical Conduit Brown, Orange Inerting Fluid Orange, Green
5.1.1.2 Colors on tapes. Tapes used to identify function shall be 1 inch minimum width. The left-hand side shall be colored, and ΒΌ inch of the right-hand side shall be reserved for geometric symbols.
5.1.1.3 Colors on painted bands. Paints used for color coding lines in accordance with
4.2.3 shall conform to the color requirements of 5.1.1 and the coding requirements of 5.1.1.1. The entire painted identification group shall completely encircle the line, and shall be of sufficient length to allow a clearance of one-half the letter height (see 5.1.3.3) between lettering and color coding on one end and between lettering and unlettered surfaces on the other end. The color coding shall appear on the left hand side of the identification group as depicted in figure 1,
6