3.13 Sympathetic reaction. The reaction of a munition or an explosive charge induced by the detonation of another like munition or explosive charge.
3.14 Threat hazard assessment (THA). An evaluation of the munition life cycle environmental profile to determine the threats and hazards to which the munition may be exposed. The assessment includes threats posed by friendly munitions, enemy munitions, accidents, handling, environmental lifecycle conditions, etc. Base the assessment on analytical or empirical data to the extent possible. The THA should also contain the potential reaction of the munition to the threats identified as well as the likely resulting collateral damage. The THA should be updated as the exposure environment changes. A source of information to guide the development of the THA may be found
in AOP-39. Paragraphs 5.2, 5.3, and table 1 of AOP-39 aid in identifying the threats to a munition as well as the configurations seen throughout the munitions lifecycle. A THA should also be properly coordinated with the Operational User, Logistician, service review organization, Program Manager, Design Authority of each participating service. The THA should take into account the worst case scenarios that the item will see in each of its intended environments.
3.15 Weapon system. A munition and those components and equipment required for its operation and support.
4. GENERAL REQUIREMENTS
4.1 General. A hazard assessment test program includes a test plan generated in concert with an environmental profile and a THA. Provide rationale for not including or modifying any hazards or tests contained or referenced in this document to the service review organization for review and approval prior to executing the test program.
4.1.1 Test plan. Develop a test plan, and base it on the life cycle environmental profile. Include in the test plan provisions for the conduct and sequence of tests, and any environmental conditioning as illustrated on figure 2. A review and concurrence is required by the appropriate service review organization(s) prior to conduct of the tests, and the review organization(s) may authorize variations to the tests and procedures in this document when justified. The test plan may