MIL-STD-2105D
and 5 of this standard to exclude any unnecessary requirements. Contractual documents must specify the following:
a. Ambient test item temperature if other than as specified (see paragraph 4.2.1).
b. When a pre-test examination is not required (see paragraphs 4.8 and 5.1.1.2).
c. The number of test items to be tested if other than as specified (see paragraph 5.1).
6.5 Submission of test reports and results. Submit copies of test reports and results to the following address for storage in the IM Hazard Classification Office (IMHCO)):
Navy/Marine Corps-(for IM): Commanding Officer
Naval Ordnance Safety & Security Activity
Farragut Hall
Attn: NOSSA, N85
3817 Strauss Ave., Suite 108
Indian Head, MD 20640-5151
6.6 Service review organizations. The following service contacts are responsible for the assessment of weapon safety and IM characteristics:
Army - (for weapon safety): Director
Chief, Safety Office
US Army Aviation and Missiles Command
ATTN: AMSAM SF
Redstone Arsenal, AL 35898 5130
Army - (for IM): Commander
U.S. Army AMRDEC
Aviation & Missile Research, Development & Engineering
Center
Attn: RDMR-WDP-M
Bldg. 7156
29
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business